GasAbate additive + Compli360 dosing system for slurry tanks containing pig slurry

Download print version

Test report 7611

The approval

A test mark „DLG-APPROVED for individual criteria“ is awarded for agricultural products which have successfully fulfilled a scope-reduced usability testing conducted by DLG according to independent and recognised evaluation criteria. The test is intended to highlight particular innovations and key criteria of the test object. The test may contain criteria from the DLG test scope for overall tests, or focus on other value-determining characteristics and properties of the test subject. The minimum requirements, test conditions and procedures as well as the evaluation bases of the test results will be specified in consultation with an expert group of DLG. They correspond to the recognised rules of technology, as well as scientific and agricultural knowledge and requirements. The successful testing is concluded with the publication of a test report, as well as the awarding of the test mark which is valid for five years from the date of awarding.

In order to obtain the certification mark, the slurry additive GasAbate + Compli360, manufactured by GlasPort Bio Ltd., was tested for its effectiveness in reducing methane emissions and odours in open slurry tanks containing pig slurry. 

The DLG’s requirements regarding the reduction of methane and odour were met and, in some cases, exceeded. Consequently, GlasPort Bio’s slurry additive for pig slurry has been certified. Other criteria were not investigated.

Assessment in brief

The slurry additive GasAbate + Compli360, manu­factured by GlasPort Bio Ltd., is a liquid chemical that is automatically added to open slurry tanks and reduces methanisation through chemical reactions. This results in less methane being produced and a reduction in odour emissions.

The product includes a dosing system that ensures that a sufficient amount of active ingredient is always added automatically and distributed throughout the container.

A 75.7 % reduction in methane levels was recorded in the slurry on an annual average basis. A reliable reduction in methane is therefore guaranteed when the product is dosed correctly.

In addition, the reduction in odour in the slurry was also verified by measurement. The use of GasAbate + Compi360 can reduce the odour in the slurry by an annual average of 79.3 %. It can therefore be assumed that, when the technology is used correctly, a reliable reduction in odour is ensured. The results are shown in Table 2.

No effect on the formation of nitrous oxide could be detected. The increase in ammonia emissions observed in some cases during the test involved only a small amount of gas and plays a minor role in an overall carbon footprint assessment.
The effects of this reduction on other gases have  not been investigated.

This certification also involved a survey of users in real-world settings. Reliable dosing in working practice can be easily demonstrated. The dosing system, which uses the active ingredient GasAbate + Compli360, therefore meets the requirements of the DLG test framework and is certified for the reduction of methane and odour.

Table 2: Measurement results at a glance

Quality PROFILETest resultEvaluation*
Reduction of Emission  
Methane reduction [%]75,7■■■■■
Odour reduction [%]79,3■■■■■

The DLG test framework specifies the following evaluation range:
 * ■■■  or better = meets, exceeds or clearly exceeds the specified DLG standard,    
■■ = meets the statutory requirements for marketing the product,
■ = failed

The product

Description and technical details

The automatic dosing system containing the active ingredient GasAbate + Compli360, manufactured by GlasPort Bio Ltd., is suitable for use in open slurry tanks with the aim of minimising emissions from stored slurry during the storage period. Table 1 sets out the key product characteristics.

The dosing system consists of a storage container (IBC) containing the liquid active ingredient, a dosing pump – the operating time of which can be recorded electronically – and several stainless-steel lances. 

During installation, the lances are fitted into the slurry tank and permanently secured. The ends of the lances are installed in such a way that any escaping GasAbate + Compli360 can rise and take effect as evenly as possible within the slurry tank. Safety regulations must be observed during use and installation. The information in the safety data sheet must be followed. Personal protective equipment (PPE) must be worn.

Warranty

The manufacturer offers a warranty of 1 year, subject to the product being used correctly.

Table 1: Product characteristics for the treatment of pig slurry (manufacturer’s specifications)

Suitability2-8 % Dry matter content
Active ingredientHydrogen peroxide
DosageAutomatic
Positive impact onMethane, nitrous oxide, ammonia, odour
Dosage for use2.49 l/m³ slurry 
Duration of useEvery 30 days
AccessoriesDosing pump, stainless steel lances, storage tank for GasAbate + Compli360
SafetyHarmless to health (GRAS) and non-biocide
Power consumption of the pump0.000562 kWh/m³ slurry

The method

The test is based on the DLG test framework for external slurry storage facilities, which was drawn up in collaboration with the Technical Committee for process-integrated mitigation measures. Large parts of the test framework are identical to the ‘VERA test protocol for covers and other emission-reducing technologies to reduce gaseous emissions from farm manure storage facilities, Version 3:2018-07’.

The test involves measurements to determine emission reductions on a pilot scale. Several identical plastic containers were used for this purpose, which were operated in a case-control mode. The purpose of this arrangement is to compare the emissions from a container holding untreated farm manure (control) with those from a container holding treated farm manure (case). The reduction is calculated from the difference.

Key process-related parameters (e.g. slurry temperature, ambient climate data and dry matter content or slurry composition) were recorded regularly and taken into account in the analysis.

Four identical tanks were available at the test site for the trial. Two tanks containing homogenised pig slurry were tested using a case-control design. For strategic reasons, the applicant decided to carry out duplicate determinations, although this is not strictly required under the DLG test framework. For this reason, all four available tanks were used for the measurements. An overview of the experimental design is shown in Table 3. Table 4 sets out the characteristics of the tanks. All tanks can be climate-controlled and are not exposed to direct sunlight. A fan in the outlet opening of each container ensures ventilation of the slurry surface, with the exhaust air being separated from the supply air as far as possible via a duct. The air velocity across the slurry surface was set at 0.1 to 0.3 m/s and was continuously recorded and stored.

During the test, care is taken to ensure that both the manufacturer’s specific requirements regarding the addition of the active substance (e.g. TM content) and standard industry requirements (e.g. agitators) are taken into account. The slurry was sourced from nearby livestock farms, agitated and distributed into the test containers 24 hours before measurements began.

The tests measured ammonia (NH3), methane (CH4) and nitrous oxide (N2O). Odour samples were also taken from all containers in order to determine technical efficiency. 

Table 3: Experimental setup for determining emission reductions in pig slurry

Container 1Container 2Container 3Container 4
Pig ControlPig CasePig ControlPig Case
Test container of the experimental setup for determining emission reductions in pig slurry (Image source: DTI)

Table 4: Characteristics of the test containers 

MaterialMDPE
ShapeCylindrical
Volume5,000 l
Height2.30 m
Inner diameter1.88 m
Ø of the inlet opening3 mm x 88 mm
Ø of the outlet opening1 mm x 200 mm

Odour

The odour concentration measurements were carried out in accordance with EN 13725:2022. The odour samples were analysed using an olfactometer. The laboratory states that the measurement uncertainty is ± 2.1 %. The samples were taken from the outlet opening of the containers. Three test days were scheduled for each of the two measurement periods, with three samples taken per container on each test day.

Ammonia

Ammonia concentrations were recorded continuously over a period of 30 days per measurement period using a PICARRO G2508 analyser (CRD spectrometer) and extracted from the outlet of the test containers. The measurements were verified by means of a 24-hour impingement measurement on one measurement day per measurement period in one test tank and one control tank. The background concentration was recorded and taken into account in the analysis. The laboratory states that the measurement uncertainty is < 1 ppb + 0.05 %.

Methane

Methane concentrations were recorded continuously over a period of 30 days per measurement period using a PICARRO G2508 analyser (CRD spectrometer) and extracted from the outlet of the test containers. Background levels were recorded and taken into account in the analysis. The laboratory stated that the measurement uncertainty was < 5 ppb + 0.02 %. During the first measurement period, methane concentrations were also recorded and analysed on a selective basis using GC/MS analysis. As there was good agreement with the continuously operating CRD spectrometer, the GC/MS technique was not used in subsequent measurements.

Nitrous oxide

Nitrous oxide concentrations were continuously recorded over a period of 30 days per measurement period using a PICARRO analyser (CRD spectrometer) and extracted from the outlet of the test containers. Background levels were recorded and taken into account in the analysis. The laboratory stated that the measurement uncertainty was < 5 ppb + 0.008 %.

Analysis of harmful gas emissions

The tests are based on the recorded slurry temperatures, so that the tests can be unambiguously assigned to the measurement periods.
Hourly averages were recorded and stored throughout the entire measurement period as part of the continuous measurements. Outliers were removed. The total of the measured values in grams was normalised to the previously measured dry weight for each test container. The two corresponding test containers (case/control) were compared and the percentage reduction determined.

Survey

Surveys on handling practices were carried out and analysed at three agricultural holdings. Where practical experience is available, tips and advice on improved handling are provided.

Documentation

The legal requirements regarding monitoring by the licensing authorities are discussed, and options are provided for the simple and sustainable documentation of correct usage.

The test results in detail

Tests were carried out on a pilot scale using several slurry tanks. The test results are based on a comparison between treated and untreated slurry, with the tanks being filled with identical slurry in each case. The results are summarised below.

The test under warm ambient conditions (summer) took place in June and August 2024. The measurements under cooler ambient conditions (autumn) took place in October and November 2024. The composition of the slurry, with ranges of variation across all test containers, is shown in Table 5. The temperature ranges in the test containers used are shown in Table 6.

During the summer measurement period, the average outdoor temperature was 17.0°C and the average relative humidity was 80.4 %. In autumn, the average temperature was 6.9°C and the average relative humidity was 90.3 %.

During the test, foaming occurred in some of the test containers. This mainly occurs during the dosing process and can be attributed to the shape of the containers. This phenomenon tends to occur more frequently in containers with a small diameter-to-height ratio.

Table 5: Composition of pig slurry before and after the series of tests

 

Summer

Autumn

 before measurementafter measurementbefore measurementafter measurement
Dry matter DM [%]    2,7    … 4,2    3,3    … 3,8    2,2    … 2,8    2,6    … 2,9
Total nitrogen [% DM]    9,26    … 13,28    9,58    … 10,90    10,39    … 11,24    9,97    … 10,57
Ammonium nitrogen [% DM]    5,88    … 9,23    6,53    … 7,77    8,47    … 9,7    8,26    … 9,05
Phosphorus [% DM]    2,10    … 2,39    2,14    … 2,22    2,14    … 2,24    2,25    … 2,44
Potassium [% DM]    5,15    … 8,03    5,48    … 6,27    7,01    … 8,76    6,70    … 8,02
pH [– –]    7,0    … 7,1    7,1    … 7,5    7,2    … 7,3    7,1    … 7,3


Table 6: Temperature and humidity in all test containers

  Summer  Autumn 
 ø-Temperatureø-Air temperatureø-Humidityø-Temperatureø-Air temperatureø-Humidity
 Slurry

above the slurry surface

Slurry

above the slurry surface

Container 1 (Control)18,1 °C17,9 °C84,2 % rH5,9 °C6,4 °C92,6 % rH
Container 2 (Case)17,8 °C17,9 °C87,6 % rH6,5 °C6,0 °C97,1 % rH
Container 3 (Control)18,3 °C17,9 °C79,5 % rH5,4 °C6,3 °C94.0 % rH
Container 4 (Case) – – [1]17,8 °C73,7 % rH6,3 °C6,1 °C89,2 % rH

[1] Sensor temporarily out of action

Odour

The average odour-causing substance mass flows generated by the untreated slurry tanks (control group) were 237,270 GE/h in summer and 225,558 GE/h in autumn. Following treatment with the additive, values of 65,868 GE/h (summer) and 30,801 GE/h (autumn) were achieved. This represented a reduction of 72.2 % in summer and 86.3 % in autumn. On average over the year, emissions were reduced by 79.3 %. The results are shown in Table 7.


Table 7: Results of the olfactometric odour measurement

 SummerAutumn
Control  
Number of measurements1717
Averaged mass flow rate of odour [GE/h]237,270225,558
Case  
Number of measurements1717
Averaged mass flow rate of odour [GE/h]65,86830,801
Odour reduction, individual [%]72,286,3
Overall odour reduction [%]

79,3

Ammonia

During the study, elevated ammonia emissions were observed in some of the treated slurry tanks, and the difference in the fall measurement was statistically significant. However, due to uncertainties in determining the dry matter content, the observed effects should be interpreted with caution. A NH3-reducing effect could not be demonstrated in this study. A supplementary analysis of the greenhouse gas impact in CO2 equivalents shows that the indirect climate impact of the increased NH3 emissions is of minor significance compared to the significantly reduced CH4 emissions. The overall positive climate impact of the CH4 reduction thus remains largely intact. The certification is limited to the reduction of methane and odour.

Methane

The results of the methane measurements were consistently good. In summer, emissions were reduced by 79.8 %, in autumn, the figure was 71.6 %, making a combined total of 75.7 %. The results are shown in Table 8.

Nitrous oxide

No significant reduction in nitrous oxide was detected over the entire duration of the test. The reduction in nitrous oxide following the addition of GasAbate + Compli360 was barely measurable and cannot be statistically substantiated. However, nitrous oxide concentrations in all slurry tanks remained at a very low level. An increase in nitrous oxide emissions resulting from the addition of Gas­Abate + Compli360 can therefore be ruled out.
 

Table 8: Results of methane measurements in pig slurry

 SummerAutumn
Control  
Measurement days [1]3027
Summed mean methane [g CH4/kg TM]26.544.30
Case  
Measurement days [1]3027
Summed mean methane [g CH4/kg TM]5.351.22
Odour reduction, individual [%]79.871.6
Overall odour reduction [%]

75.7

Survey

The survey of three farmers yielded predominantly positive results. Two of the three farmers added the additive to their tanks of pig slurry, whilst one farmer used a tank of cattle manure. As the set-up is identical and the method of application differs only slightly, the statements from all three farmers can be taken into account equally in the survey.

The automatic dosing was found to be particularly convenient. This meant that the time required by the operators was kept to a minimum. The fact that there was no need for additional stirring was also well ­received. A follow-up survey carried out at one of the three farms two years after installation revealed that even the operation of a mobile agitator had not caused any visible damage to the pipework. However, all operators would like to have a control display (if no logger station has been installed) or remote monitoring (e.g. via a mobile app). An alarm relay or an additional level sensor in the IBC container could also be bene­ficial. Installation should be carried out by the manufacturer’s qualified personnel.

The time required was stated as ten minutes per week, provided that the active ingredient (IBC container) does not need to be replaced; otherwise, an additional two hours per IBC container should be allowed for.
All participants in the survey would use the technology again at any time if its positive effects were con­clusively proven.

Documentation

The operation of the dosing pump can be recorded via a data logger (optional) and saved in tabular form, including the date and time. In addition, purchase receipts for the active ingredient can be collated. This enables regulatory authorities to monitor the sustainable use of the dosing system.

Conclusion

The study involved technical measurements to reduce odour and methane emissions from an external slurry tank containing pig slurry under laboratory conditions. The additive for pig slurry was assessed for ease of use in practical applications, and a survey was carried out amongst operators.

Based on the available results, the additive GasAbate + Compli360, when used with the dosing system supplied by GlasPort Bio Ltd., meets the requirements for the award of the DLG Quality Seal in respect of the test criteria ‘Odour and methane emission reduction’. The composition of the active ingredient is assessed and awarded an accolade annually.

No other criteria were assessed.

Manufacturer and test implementation

Manufacturer and applicant

GlasPort Bio Ltd., Unit 1, 
Galway Business Park, 
Galway, H91 EFD0, 
Republic of Ireland

Contact: 
Phone +353 (087) 9788911
info@glasportbio.com 
https://www.glasportbio.com 


Test implementation

DLG TestService GmbH, Gross-Umstadt location, Germany
The tests are conducted on behalf of DLG e.V.

DLG test framework
DLG APPROVED test “Emission reduction in slurry tanks” (current as of 08/2026)

Department
Farm Inputs

Farm inputs
Dr. Michael Eise

Farm inputs
Dipl.-Ing. (FH) Tommy Pfeifer*

Technical Committee

Dr Gunnar Brehme, Wiesenhof
Frank Geburek, District Coesfeld
Dr David Janke, ATP Potsdam
Alfons Krafeld, LWK NRW
Prof Dr Jörg Oldenburg, Engineering office

*Author