Download print version
Test report 7408
The approval
The DLG APPROVED FULL TEST quality mark is awarded to agricultural equipment that has passed a comprehensive DLG usability test. A DLG usability test is carried out to independent and recognised test criteria and provides an objective and unbiased assessment of the product and all features considered essential by users. The test comprises individual lab tests as well as field tests in various conditions; in addition to that the product has to prove itself in on-farm applications. The test conditions and procedures are defined by an independent test commission and described in a test framework which defines the parameters for evaluation. Yet the test conditions and procedures as defined are revised on an ongoing basis so they reflect what is acknowledged as the current state of the art as well as the latest scientific findings and also agricultural insights and requirements. After a product has passed the test, a test report is produced and published and the quality mark is awarded to the product and will retain its validity for five
years from the date of award. Subject of the test was the two stage air cleaning system „EMMI Pig“ from SCHULZ Systemtechnik GmbH. The cleaner operates on the pressure principle and the filter load must not exceed 5,000 m³/(m² · h) to obtain the system functionality. In the chemical stage the minimum sprinkling density must be 2.0 m³/(m² · h) and in the biological stage 1.0 m³/(m² · h). The maximum conductivity in the process water was 220 mS/cm (chemical) and 20 mS/cm (biological). The process water ph was 2.4±0.5 (chemical) and between 6.3 and 6.9 (biological).
Test results
Test criterion | Result/Value | Evaluation* |
---|---|---|
Description | ||
Chemical and biological air cleaning system with continuous irrigation | ||
Suitability | ||
Purification of exhaust air from strawless pig housing with overhead ventilation and using usual feed by reducing dust, ammonia and odour emissions | ||
Total dust | ||
Minimum separation rate, winter/summer | 87.8 % / 74.8 % | ✔ |
Finde dust PM10 | ||
Minimum separation rate, winter/summer | 82.9 % / 72.4 % | ✔ |
Ammonia | ||
Minimum separation rate after chemical stage, winter/summer | 89.7 % / 86.5 % | ✔ |
Minimum separation rate after chemical stage and biological stage, winter/summer | 90.7 % / 87.0 % | ✔ |
Nitrogen removal | ||
Chemical stage/chemical and biological stage, summer | 81.2 % / 87.3 % | ✔ |
Odour | ||
Winter/summer | < 300 OU/m³, no uncleaned gas perceived | ✔ |
* Evaluation range: Meets the requirement (✔) / Does not meet the requirement (X)
Explanations: The minimum separation rate for dust is the lowest measurement recorded in the test period. The minimum ammonia separation rate is the averaged separation efficiency minus the standard deviation. One winter measurement on N removal was not plausible. Therefore only the result of the N balance under summer conditions was given. Dust and odour reduction is only ensured using the entire cleaning system. The chemical stage and the demister must be cleaned regularly.
You can find the detailed test report in German at the Internetaddress:
www.dlg.org/de/landwirtschaft/tests/pruefberichte/innenwirtschaft/test-schulz-abluftreinigungsanlage-emmi-pig
Manufacturer and applicant
SCHULZ Systemtechnik GmbH
Schneiderkruger Straße 12
9429 Visbek
Germany
Contact:
Telephone +49 (0)4445-897-0,
info@schulz.st, www.schulz.st
Contact us
DLG TestService GmbH - Groß-Umstadt location • Max-Eyth-Weg 1 • 64823 Groß-Umstadt • Tel: +49 69 24 788-600 • tech@DLG.org